Factory Fabricated PVC Pipe Boots
Boot Installation Instructions:
Step 1:
Prepare the subgrade around the area of the pipe. The sub-grade must be smooth, uniform, and free of any protrusions.
Step 2:
Clean the surface of the liner around the penetration where the boot will be welded in place. Wipe away any dirt or dust particles. The surfaces of the liner, boot, and the pipe must be completely clean and dry.
Step 3:
Slide the boot sleeve on the pipe, making sure the boot is aligned and all surfaces are smooth. It may be necessary to trim the excess tapered portion of the boot sleeve.
Step 4:
Weld the boot apron to the liner using PVC to PVC Glue. Apply the adhesive to the liner and the boot apron. Let the adhesive setup for several seconds before pressing the boot apron and the liner together using a roller. Make sure to smooth out any bubbles or wrinkles.
Step 5:
Seal the boot sleeve to the pipe using the stainless steel hose clamps provided. The clamps around the pipe will form a watertight seal to the pipe.
Vertical or horizontal boots are available for all standard size pipes up to 12" diameter. Larger sizes can be custom made. Provide the outside diameter of the pipe for quotations.
Return To PVC Products Page
Return To Geomembranes Products Page
![]()
[HOME | PRODUCTS | SPECIALS | RELATED INFORMATION]
[CONTACT US! | WHAT'S NEW | ABOUT]
![]()
GeoCHEM, Inc. Business Page © 1997 - 2008 GeoCHEM, Incorporated All Rights Reserved.